Datasheet
16 TMC223 DATASHEET (V. 1.00 / May 3rd, 2007)
Copyright © 2007 TRINAMIC Motion Control GmbH & Co. KG
5.1.12 Temperature Management
The TMC223 provides an internal temperature monitoring. The circuit goes into shutdown mode if the
temperature exceeds threshold T
tsd
, furthermore two thresholds are implemented to generate a
temperature pre-warning.
Low Temperatur
<Tinfo> = "01"
<TW> = '0'
<TSD> = '0'
Normal Temp.
<Tinfo> = "00"
<TW> = '0'
<TSD> = '0'
Thermal Warning
<Tinfo> = "10"
<TW> = '1'
<TSD> = '0'
Post
Thermal Warning
<Tinfo> = "00"
<TW> = '1'
<TSD> = '0'
T° > TlowT° < Tlow
Thermal Shutdown
<Tinfo> = "11"
<TW> = '1'
<TSD> = '1'
SoftStop, if motion
Motion = disabled
Post Thermal
Shutdown 1
<Tinfo> = "10"
<TW> = '1'
<TSD> = '1'
Motion = disabled
Post Thermal
Shutdown 2
<Tinfo> = "00"
<TW> = '1'
<TSD> = '1'
Motion = disabled
T° > Ttw
T° > TtsdT° < TtwT° > Ttw
T° < TtsdT° > Ttsd
T° < TtwT° > Ttw
T° < Ttw &
GetFullStatus1
T° < Ttw &
GetFullStatus1