Datasheet
TMC220X, TMC222X DATASHEET (Rev. 1.02 / 2017-MAY-16) 70
www.trinamic.com
Linear regulator
DC-Characteristics
V
VS
= V
VSA
= 24.0V
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Output voltage
V
5VOUT
I
5VOUT
= 0mA
T
J
= 25°C
4.80
5.0
5.25
V
Output resistance
R
5VOUT
Static load
1
Deviation of output voltage over
the full temperature range
V
5VOUT(DEV)
I
5VOUT
= 5mA
T
J
= full range
+/-30
+/-100
mV
Deviation of output voltage over
the full supply voltage range
V
5VOUT(DEV)
I
5VOUT
= 5mA
V
VS
= variable
+/-15
+/-30
mV /
10V
Clock oscillator and input
Timing-Characteristics
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Clock oscillator frequency
(factory calibrated)
f
CLKOSC
t
J
=-50°C
11.7
MHz
f
CLKOSC
t
J
= 25°C
11.5
12.0
12.5
MHz
f
CLKOSC
t
J
=150°C
12.1
MHz
External clock frequency
(operating)
f
CLK
4
10-16
18
MHz
External clock high / low level
time
t
CLK
CLK driven to
0.1 V
VIO
/ 0.9 V
VIO
10
ns
External clock timeout detection
in cycles of internal f
CLKOSC
x
timeout
External clock stuck
at low or high
32
48
cycles
f
CLKOSC