TMC2160 DATASHEET (Rev. 1.00 / 2018-JUL-30) 85
www.trinamic.com
When the microstep sequencer advances within the table, it calculates the actual current values for
the motor coils with each microstep and stores them to the registers CUR_A and CUR_B. However, the
incremental coding requires an absolute initialization, especially when the microstep table becomes
modified. Therefore CUR_A and CUR_B become initialized whenever MSCNT passes zero.
Two registers control the starting values of the tables:
- As the starting value at zero is not necessarily 0 (it might be 1 or 2), it can be programmed
into the starting point register START_SIN.
- In the same way, the start of the second wave for the second motor coil needs to be stored
in START_SIN90. This register stores the resulting table entry for a phase shift of 90° for a 2-
phase motor.
Hint
Refer chapter 5.3 for the register set and for the default table function stored in the drivers. The
default table is a good base for realizing an own table.
The TMC2160-EVAL comes with a calculation tool for own waves.
Initialization example for the default microstep table:
MSLUT[0]= %10101010101010101011010101010100 = 0xAAAAB554
MSLUT[1]= %01001010100101010101010010101010 = 0x4A9554AA
MSLUT[2]= %00100100010010010010100100101001 = 0x24492929
MSLUT[3]= %00010000000100000100001000100010 = 0x10104222
MSLUT[4]= %11111011111111111111111111111111 = 0xFBFFFFFF
MSLUT[5]= %10110101101110110111011101111101 = 0xB5BB777D
MSLUT[6]= %01001001001010010101010101010110 = 0x49295556
MSLUT[7]= %00000000010000000100001000100010 = 0x00404222
MSLUTSEL= 0xFFFF8056:
X1=128, X2=255, X3=255
W3=%01, W2=%01, W1=%01, W0=%10
MSLUTSTART= 0x00F70000:
START_SIN_0= 0, START_SIN90= 247
17 Emergency Stop
The driver provides a negative active enable pin ENN to safely switch off all power MOSFETs. This
allows putting the motor into freewheeling. Further, it is a safe hardware function whenever an
emergency-stop not coupled to software is required. Some applications may require the driver to be
put into a state with active holding current or with a passive braking mode. This is possible by
programming the pin DCIN to act as a step disable function. Set GCONF flag stop_enable to activate
this option. Whenever DCIN becomes pulled up, the motor will stop abruptly and go to the power
down state, as configured via IHOLD, IHOLD_DELAY and stealthChop standstill options. Disabling the
driver via ENN will require three clock cycles to safely switch off the driver.