Datasheet
TMC2041 DATASHEET (Rev. 1.02 / 2017-MAY-16) 52
www.trinamic.com
ENABLING COOLSTEP (ONLY IN COMBINATION WITH SPREADCYCLE)
Enable coolStep
Move the motor by slowly
accelerating from 0 to
operation velocity V
Does SG_RESULT go down
to 0 with load?
Monitor SG_RESULT value
during medium velocity and
check response with
mechanical load
Is coil current sine-
shaped at V?
Decrease VN
Y
Increase SGTY
COOLCONF
Enable coolStep basic config.:
SEMIN=1, all other 0
N
Set VCOOLTHRS
to the lower velocity
limit for coolStep
Monitor CS_ACTUAL during
motion in velocity range
and check response with
mechanical load
Does CS_ACTUAL reach
IRUN with load before
motor stall?
Increase SEMIN or
choose narrower
velocity limits
N
C2
C2
Monitor CS_ACTUAL and
motor torque during rapid
mechanical load increment
within application limits
Does CS_ACTUAL reach
IRUN with load before
motor stall?
Increase SEUPN
Finished
Figure 13.2 Enabling coolStep (only in combination with spreadCycle)