Datasheet

TMC2130 DATASHEET (Rev. 1.09 / 2017-MAY-15) 91
www.trinamic.com
Linear regulator
DC-Characteristics
V
VS
= V
VSA
= 24.0V
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Output voltage
V
5VOUT
I
5VOUT
= 0mA
T
J
= 25°C
4.80
5.0
5.25
V
Output resistance
R
5VOUT
Static load
3
Deviation of output voltage over
the full temperature range
V
5VOUT(DEV)
I
5VOUT
= 16mA
T
J
= full range
+/-30
+/-100
mV
Deviation of output voltage over
the full supply voltage range
V
5VOUT(DEV)
I
5VOUT
= 0mA
V
VSA
= variable
+/-15
+/-30
mV /
10V
Deviation of output voltage over
the full supply voltage range
V
5VOUT(DEV)
I
5VOUT
= 16mA
V
VSA
= variable
-38
+/-75
mV /
10V
Clock oscillator and input
Timing-Characteristics
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Clock oscillator frequency
f
CLKOSC
t
J
=-50°C
9
12.4
MHz
Clock oscillator frequency
f
CLKOSC
t
J
=50°C
10.1
13.2
17.2
MHz
Clock oscillator frequency
f
CLKOSC
t
J
=150°C
13.4
18
MHz
External clock frequency
(operating)
f
CLK
4
10-16
18
MHz
External clock high / low level
time
t
CLKH
/
t
CLKL
CLK driven to
0.1 V
VIO
/ 0.9 V
VIO
10
ns
External clock first cycle
triggering switching to external
clock source
t
CLKH1
CLK driven high
30
25
ns
Detector levels
DC-Characteristics
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
V
VSA
undervoltage threshold for
RESET
V
UV_VSA
V
VSA
rising
3.8
4.2
4.6
V
V
5VOUT
undervoltage threshold for
RESET
V
UV_5VOUT
V
5VOUT
rising
3.5
V
V
VCC_IO
undervoltage threshold for
RESET
V
UV_VIO
V
VCC_IO
rising (delay
typ. 10µs)
2.1
2.55
3.0
V
V
VCC_IO
undervoltage detector
hysteresis
V
UV_VIOHYST
0.3
V
Short to GND detector threshold
(V
VS
- V
Ox
)
V
OS2G
2
2.5
3
V
Short to GND detector delay
(high side switch on to short
detected)
t
S2G
High side output
clamped to V
SP
-3V
0.8
1.3
2
µs
Overtemperature prewarning
t
OTPW
Temperature rising
100
120
140
°C
Overtemperature shutdown
t
OT
Temperature rising
135
150
170
°C