User Manual
QBL4208 Manual (V1.01 / 2008-04-01) 5
Copyright © 2008, TRINAMIC Motion Control GmbH & Co. KG
3 Mechanical Dimensions
3.1 Leadwire Configuration
Cable type 1 No. Gauge Function
Red
1 UL1007 AWG26
Vcc Hall Sensor
+5VDC to +24VDC
Blue
2 UL1007 AWG26 Hall A
Green
3 UL1007 AWG26 Hall B
White
4 UL1007 AWG26 Hall C
Black
5 UL1007 AWG26
GND Hall
Sensor Ground
Black
6 UL1007 AWG20 Phase U
Red
7 UL1007 AWG20 Phase V
Yellow
8 UL1007 AWG20 Phase W
Table 3.1: Leadwire configuration
3.2 Dimensions
Figure 3.1: Dimensions (all values in mm)