User Manual

TMCM-1180 and PD86-1180 Hardware Manual (V1.01 / 2011-MAR-21) 20
Copyright © 2011, TRINAMIC Motion Control GmbH & Co. KG
6 Operational ratings
The operational ratings shown below should be used as design values. In no case should the maximum
values been exceeded during operation.
Symbol
Parameter
Min
Typ
Max
Unit
+U
Driver
/ +U
Logic
Power supply voltage for operation
18
24 or 48
55
V DC
I
COIL_peak
Motor coil current for sine wave peak
(chopper regulated, adjustable via
software)
0
7.8
A
I
COIL_RMS
Continuous motor current (RMS)
0
5.5
A
I
SUPPLY
Power supply current
<< I
COIL
1.4 * I
COIL
A
T
ENV
Environment temperature at rated
current (no forced cooling required)
-20
+50
*)
°C
Table 4.6.1: General operational ratings of the module
*) The controller driver electronics has been tested inside a climate chamber running at full current (5.5A
RMS) for 30min without air convection at 50°C environmental temperature.
Please note: The motor might heat up well above 50°C when running at full current without proper
cooling. This might substantially increase the environmental temperature for the electronics. When
using the coolStepoperation mode, the actual current might be substantially less than programmed
max. current producing and temperature.