User Manual

PD57/60-1276 Hardware Manual Hardware Version V1.10 | Document Revision V1.02 2018-SEP-03
18 / 24
6 Operational Ratings and Characteristics
6.1 Absolute Maximum Ratings
Parameter Min Max Unit
Supply voltage +10 +30 V
Working temperature -20 +50 ° C
Motor coil current / sine wave peak 4.2 A
Continuous motor current (RMS) 3.0 A
NOTICE
Stresses above those listed under "Absolute Maximum Ratings" may cause per-
manent damage to the device. This is a stress rating only and functional operation
of the device at those or any other conditions above those indicated in the op-
eration listings of this specication is not implied. Exposure to maximum rating
conditions for extended periods may aect device reliability.
6.2 Electrical Characteristics (Ambient Temperature 25° C)
Parameter Symbol Min Typ Max Unit
Supply voltage V DD 10 24 30 V
Motor coil current / sine wave
peak
(chopper regu-
lated, adjustable via TTL UART interface)
I
COILpeak
0 4.2 A
Continuous motor current (RMS) I
COILRMS
0 3.0 A
Power supply current I
DD
I
COIL
1.4I
COIL
A
Table 10: Electrical Characteristics
6.3 I/O Ratings (Ambient Temperature 25° C)
Parameter Symbol Min Typ Max Unit
Input voltage V
IN
5 5.5 V
Low level voltage V
L
0 1.5 V
High level voltage V
H
3.5 5 V
Table 11: I/O ratings
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com