User Manual

PD57/60/86-x-1260 Hardware Manual Hardware Version V1.10 | Document Revision V1.20 2019-03-22
15 / 41
Connector Connector type on-board Mating connector type
USB USB-micro B female connector USB-micro B male connector
I/O JST B8B-PH-K-S
(JST PH series, 8pins, 2mm pitch)
Connector housing: JST PHR-8
Contacts: JST SPH-002T-P0.5S
Wire: 0.22mm2, AWG 24
Table 4: Connector Types and Mating Connectors of the PD57/60/86-x-1260
4.1 Power Supply Input Connector
The PD57/60/86-x-1260 oers one 4pin JST VH series power supply input connector. In addition to main
power supply input and related ground connection this connector oers a separate logic supply input
with the option to keep the on-board logic alive while the driver stage is switched o. It is not necesary to
connect the logic supply input in case separate supplies are not required as the main power supply input
will always supply power to the driver stage and the logic part.
The power supply input connector oers a driver enable input. This input has to be connected to any
voltage above 3.5V up-to max. supply voltage of 54V in order to enable the driver stage. Leaving this pin
unconnected or connected to ground (voltage below 2.4V) will disable the driver stage regardless of any
settings in software. This input may be connected to main power supply input permanently in case an
enable input in hardware is not required.
Power Supply Connector Pin Assigment
Pin Label Direction Description
1 GND Power (GND) Common system supply and signal ground
2 V
MAIN
Power (input) Main power supply input for the driver and on-board logic
12. . . 54V
3 Enable Digital input
Driver enable input. A voltage above 3.5V is required here
in order to enable the on-board stepper motor driver. This
input maybe connected to main power supply input in order
to enable the driver stage.
4 V
LOGIC
Power (input) Optional separate power supply input for the on-board logic
12. . . 54V
Table 5: Power Supply Connector Pin Assignment
NOTICE
Do not connect or disconnect motor during operation!
Motor cable and mo-
tor inductivity might lead to voltage spikes when the motor is (dis)connected
while energized. These voltage spikes might exceed voltage limits of the driver
MOSFETs and might permanently damage them. Therefore, always switch o
/ disconnect power supply or at least disable driver stage before connecting /
disconnecting motor.
NOTICE
Take care of polarity, wrong polarity can destroy the board!
NOTICE
Connect Enable pin to voltage >3.5V in order to enable motor movements!
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com