All Global Parameters of the PD57/60-1260 Module in Bank 0
Number Global Parameter Description Range [Units] Access
65 RS485 baud rate
0 9600 Default
1 14400
2 19200
3 28800
4 38400
5 57600
6 76800
7 115200
8 230400
0. . . 8 RWA
66 Serial address Module (target) address for RS485. 1. . . 255 RWA
68 Serial heartbeat
Serial heartbeat for RS485 interface and
USB interface. If this time limit is up and no
further command is received by the mod-
ule the motor will be stopped. Setting this
parameter to 0 (default) turns off the serial
heartbeat function.
0. . . 65535 [ms] RWA
69 CAN bit rate
2 20kBit/s
3 50kBit/s
4 100kBit/s
5 125kBit/s
6 250kBit/s
7 500kBit/s
8 1000kBit/s (Default)
2. . . 8 RWA
70 CAN reply ID
The CAN ID for replies from the board (de-
fault: 2).
0. . . 2047 RWA
71 CAN ID
The module (target) address for CAN (de-
fault: 1).
0. . . 2047 RWA
75 Telegram pause
time
Pause time before the reply via RS485 is
sent. For use with older RS485 interfaces it
is often necessary to set this parameter to
15 or more (e.g. RS485 adapters controlled
by the RTS pin). For CAN interface this pa-
rameter has no effect!
0. . . 255 RWA
76 Serial host
address
Host address used in the reply telegrams
sent back via RS485.
0. . . 255 RWA