User Manual
PD57/60-1260 TMCL
™
Firmware Manual • Firmware Version V1.44 | Document Revision V1.02 • 2018-SEP-05
78 / 107
Number Axis Parameter Description Range [Units] Access
185 Chopper syn-
chronization
This parameter allows synchronization of the
chopper for both phases of a two phase motor
in order to avoid the occurrence of a beat, espe-
cially at low velocities.
0: chopper sync function chopSync off
1. . . 15: chopper synchronization
0. . . 15 RW
186
PWM threshold
speed
The StealthChop feature will be switched off
when the actual velocity is higher than this value.
It will be switched on when the actual velocity is
below this value (and parameter #187 is greater
than zero).
0. . . 7999774
[pps]
RW
187 PWM gradient
Velocity dependent gradient for PWM amplitude
(StealthChop). Setting this value to 0 turns off
StealthChop.
0..15 RW
188 PWM
amplitude
Maximum PWM amplitude when switching to
StealthChop mode. Do not set too low. Values
above 64 recommended.
0..255 RW
189 PWM scale
Actual PWM amplitude scaler (255=maximum
voltage). In voltage mode PWM, this value allows
to detect a motor stall.
0. . . 255 R
190 PWM mode
Status of StealthChop voltage PWM mode (de-
pending on velocity thresholds).
0 - StealthChop disabled
1 - StealthChop enabled
0/1 R
191 PWM
frequency
PWM frequency selection for StealthChop.
0 - f
PWM
= 15.625kHz
1 - f
PWM
= 23.426kHz
2 - f
PWM
= 31.250kHz
3 - f
PWM
= 39.024kHz
0. . . 3 RW
192
PWM autoscale
PWM automatic amplitude scaling for Stealth-
Chop.
0 - User defined PWM amplitude. The current
settings do not have any influence.
1 - Enable automatic current control.
0. . . 1 RW