Most motor controller features of the PD57/60-1260 module are controlled by axis parameters. Axis
parameters can be modied or read using SAP, GAP and AAP commands. This chapter describes all axis
parameters that can be used on the PD57/60-1260 module.
Meaning of the Letters in the Access Column
Access type Command Description
R GAP Parameter readable
W SAP, AAP Parameter writable
Table 14: Meaning of the Letters in the Access Column
All Axis Parameters of the PD57/60-1260 Module
Number Axis Parameter Description Range [Units] Access
0 Target position The desired target position in position mode -2147483648
. . . 2147483647
[µsteps]
RW
1 Actual position
The actual position of the motor. Stop the motor
before overwriting it. Should normally only be
overwritten for reference position setting.
-2147483648
. . . 2147483647
[µsteps]
RW
2 Target speed
The desired speed in velocity mode. Not valid in
position mode.
-7999774
. . . 7999774
[pps]
RW
3 Actual speed The actual speed of the motor. -7999774
. . . 7999774
[pps]
R
4 Maximum
positioning
speed
The maximum speed used for positioning
ramps.
0. . . 7999774
[pps]
RW
5 Maximum
acceleration
Maximum acceleration in positioning ramps. Ac-
celeration and deceleration value in velocity
mode.
0. . . 7629278
[pps
2
]
RW
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.