The special functions of bit 2, 3 and 4 are shown in table 22. Add these values to the value supplied to the
SAP 217 command to activate these functions.
Special Encoder Functions
Bit Value (add to <p>) Function
2 4 If set the encoder will be zeroed with next null channel event.
3 8
If set in combination with bit 2: Encoder will be zeroed with each null
channel event.
4 16 Null channel polarity for encoder clearing:
0 - low
1 - high
Table 22: Special Encoder Functions