User Manual
Table Of Contents
- 1 Features
- 2 First Steps with TMCL
- 3 TMCL and the TMCL-IDE — An Introduction
- 3.1 Binary Command Format
- 3.2 Reply Format
- 3.3 Standalone Applications
- 3.4 The ASCII Interface
- 3.5 TMCL Command Overview
- 3.6 TMCL Commands by Subject
- 3.7 Detailed TMCL Command Descriptions
- 3.7.1 ROR (Rotate Right)
- 3.7.2 ROL (Rotate Left)
- 3.7.3 MST (Motor Stop)
- 3.7.4 MVP (Move to Position)
- 3.7.5 SAP (Set Axis Parameter)
- 3.7.6 GAP (Get Axis Parameter)
- 3.7.7 STAP (Store Axis Parameter)
- 3.7.8 RSAP (Restore Axis Parameter)
- 3.7.9 SGP (Set Global Parameter)
- 3.7.10 GGP (Get Global Parameter)
- 3.7.11 STGP (Store Global Parameter)
- 3.7.12 RSGP (Restore Global Parameter)
- 3.7.13 RFS (Reference Search)
- 3.7.14 SIO (Set Output)
- 3.7.15 GIO (Get Input)
- 3.7.16 CALC (Calculate)
- 3.7.17 COMP (Compare)
- 3.7.18 JC (Jump conditional)
- 3.7.19 JA (Jump always)
- 3.7.20 CSUB (Call Subroutine)
- 3.7.21 RSUB (Return from Subroutine)
- 3.7.22 WAIT (Wait for an Event to occur)
- 3.7.23 STOP (Stop TMCL Program Execution – End of TMCL Program)
- 3.7.24 SCO (Set Coordinate)
- 3.7.25 GCO (Get Coordinate)
- 3.7.26 CCO (Capture Coordinate)
- 3.7.27 ACO (Accu to Coordinate)
- 3.7.28 CALCX (Calculate using the X Register)
- 3.7.29 AAP (Accu to Axis Parameter)
- 3.7.30 AGP (Accu to Global Parameter)
- 3.7.31 CLE (Clear Error Flags)
- 3.7.32 EI (Enable Interrupt)
- 3.7.33 DI (Disable Interrupt)
- 3.7.34 VECT (Define Interrupt Vector)
- 3.7.35 RETI (Return from Interrupt)
- 3.7.36 Customer specific Command Extensions (UF0…UF7 – User Functions)
- 3.7.37 Request Target Position reached Event
- 3.7.38 TMCL Control Commands
- 4 Axis Parameters
- 5 Global Parameters
- 6 Module Specific Hints
- 7 Hints and Tips
- 8 TMCL Programming Techniques and Structure
- 9 Figures Index
- 10 Tables Index
- 11 Supplemental Directives
- 12 Revision History

PD-1160 TMCL
™
Firmware Manual • Firmware Version V1.42 | Document Revision V1.06 • 2018-JAN-09
87 / 113
All Global Parameters of the PD-1160 Module in Bank 0
Number Global Parameter Description Range [Units] Access
65 RS485 baud rate
0 9600 Default
1 14400
2 19200
3 28800
4 38400
5 57600
6 76800
7 115200
8 230400
0. . . 8 RWA
66 Serial address Module (target) address for RS485. 1. . . 255 RWA
67 ASCII Mode Configure the TMCL ASCII interface:
Bit 0 0 - start up in binary (normal) mode
1 - start up in ASCII mode
Bits 4 & 5 00 - Echo back each character
01 - Echo back complete command
10 - Do not send echo, only send com-
mand reply
0. . . 63 RWA
68 Serial heartbeat
Serial heartbeat for RS485 interface and
USB interface. If this time limit is up and no
further command is received by the mod-
ule the motor will be stopped. Setting this
parameter to 0 (default) turns off the serial
heartbeat function.
0. . . 65535 RWA
69 CAN bit rate
2 20kBit/s
3 50kBit/s
4 100kBit/s
5 125kBit/s
6 250kBit/s
7 500kBit/s
8 1000kBit/s (Default)
2. . . 8 RWA
70 CAN reply ID
The CAN ID for replies from the board (de-
fault: 2).
0. . . 2047 RWA
71 CAN ID
The module (target) address for CAN (de-
fault: 1).
0. . . 2047 RWA
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany