User Manual

Table Of Contents
PD-1160 TMCL
Firmware Manual Firmware Version V1.42 | Document Revision V1.06 2018-JAN-09
87 / 113
All Global Parameters of the PD-1160 Module in Bank 0
Number Global Parameter Description Range [Units] Access
65 RS485 baud rate
0 9600 Default
1 14400
2 19200
3 28800
4 38400
5 57600
6 76800
7 115200
8 230400
0. . . 8 RWA
66 Serial address Module (target) address for RS485. 1. . . 255 RWA
67 ASCII Mode Congure the TMCL ASCII interface:
Bit 0 0 - start up in binary (normal) mode
1 - start up in ASCII mode
Bits 4 & 5 00 - Echo back each character
01 - Echo back complete command
10 - Do not send echo, only send com-
mand reply
0. . . 63 RWA
68 Serial heartbeat
Serial heartbeat for RS485 interface and
USB interface. If this time limit is up and no
further command is received by the mod-
ule the motor will be stopped. Setting this
parameter to 0 (default) turns o the serial
heartbeat function.
0. . . 65535 RWA
69 CAN bit rate
2 20kBit/s
3 50kBit/s
4 100kBit/s
5 125kBit/s
6 250kBit/s
7 500kBit/s
8 1000kBit/s (Default)
2. . . 8 RWA
70 CAN reply ID
The CAN ID for replies from the board (de-
fault: 2).
0. . . 2047 RWA
71 CAN ID
The module (target) address for CAN (de-
fault: 1).
0. . . 2047 RWA