3.7.2 ROL (Rotate Left)
The motor is instructed to rotate with a specied velocity in left direction (decreasing the position counter).
The velocity is given in internal units ([int]) of the TMC429 motion controller used on the PD-1160 module.
Please see also section 6.1.
Internal function:
First, velocity mode is selected.
Then, the velocity value is transferred to axis parameter #2 (target velocity).
Related commands: ROR, MST, SAP, GAP.
Mnemonic: ROL <axis>, <velocity>
Binary Representation
Instruction Type Motor/Bank Value
2 0 0 -2047. . . 2047
Reply in Direct Mode
Status Value
100 - OK dont care
Example
Rotate left motor 0, velocity 1000.
Mnemonic: ROL 0, 1000.
Binary Form of ROL 0, 1000
Field Value
Target address 01
h
Instruction number 02
h
Type 00
h
Motor/Bank 00
h
Value (Byte 3) 00
h
Value (Byte 2) 00
h
Value (Byte 1) 03
h
Value (Byte 0) E8
h
Checksum EE
h
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany