Operational Ratings of the I/Os
Symbol Parameter Min Typ Max Unit
Table 13: Operational ratings of I/Os
Operational Ratings of the RS485 Interface
Symbol Parameter Min Typ Max Unit
N
RS485
Number of nodes connected to single RS485 network 256
f
RS485
Max. speed for RS485 network 1Mbit/s
Table 14: Operational ratings of the RS485 interface
Operational Ratings of the CAN Interface
Symbol Parameter Min Typ Max Unit
N
CAN
Number of nodes connected to single CAN network >110
f
CAN
Max. speed for CAN network 1Mbit/s
Table 15: Operational ratings of the CAN interface