User Manual

PD42-1140 CANopen® Firmware Manual Firmware Version V3.20 | Document Revision V2.10 2018-DEC-01
37 / 109
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 13 0
Table 73: Entry Description (2085
h
)
4.2.11 Object 2086
h
: Pulse Divisor
Use this object to dene the pulse divisor when internal units are selected for velocity and acceleration.
Writing to this object is only possible in SWITCHED_ON_DISABLED state. The velocity pre-scaler should be
decremented or incremented carefully (in steps of one).
Object Description
Index Name Object Type Data Type
2086
h
Ramp Divisor Variable UNSIGNED8
Table 74: Object Description (2086
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 13 0
Table 75: Entry Description (2086
h
)
4.2.12 Object 2087
h
: Maximum Velocity
The functionality of this object depends on the unit selection (refer to object 208C
h
).
If internal units are selected this object will be set to the xed value of 2047 and cannot be changed.
If user units are selected the maximum velocity (RPM or PPS) that is to be used must be set here. A
lower value in this object leads to a better accuracy of the unit conversion.
This value can only be changed when the drive is in SWITCHED_ON_DISABLED state.
Object Description
Index Name Object Type Data Type
2087
h
Ramp Divisor Variable UNSIGNED32
Table 76: Object Description (2087