3.6.7 STAP (Store Axis Parameter)
This command is used to store TMCL axis parameters permanently in the EEPROM of the module. This
command is mainly needed to store the default configuration of the module. The contents of the user
variables can either be automatically or manually restored at power on.
Info
For a table with parameters and values which can be used together with this
command please refer to dection 4.
Internal function:
The axis parameter specified by the type and bank number will be stored in the
EEPROM.
Related commands: SAP, AAP, GAP, RSAP.
Mnemonic: STAP <parameter number>, <bank>
Binary Representation
Instruction Type Motor/Bank Value
7 see chapter 4 0 0 (don’t care)
Reply in Direct Mode
Status Value
100 - OK 0 (don’t care)
Example
Store axis parameter #6.
Mnemonic: STAP 7, 6.
Binary Form of STAP 6, 12
Field Value
Target address 01
h
Instruction number 07
h
Type 06
h
Motor/Bank 00
h
Value (Byte 3) 00
h
Value (Byte 2) 00
h
Value (Byte 1) 00
h
Value (Byte 0) 00
h
Checksum 0E
h
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany