User Manual

Table Of Contents
PD42-x-1670 CANopen Firmware Manual Firmware Version V2.0 | Document Revision V1.0 2018-Nov-07
70 / 86
Entry Description
Sub- PDO
index Name Mapping Min Max Default Unit Access
0 Homing Acceleration no 0 100000 2000 [rpm/s] RW
Table 198: Entry Description (609A
h
)
8.2.8 Object 2100
h
: Home Oset Display
This object shows the home oset. The value is given in encoder or hall increments.
Object Description
Index Name Object Type Data Type
2100
h
Home Oset Display Variable SIGNED32
Table 199: Object Description (2100
h
)
Entry Description
Sub- PDO
index Name Mapping Min Max Default Unit Access
0 Home Oset Display no -2147483648 2147483647 0 R
Table 200: Entry Description (2100
h
)
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com