User Manual

Table Of Contents
PD42-x-1670 CANopen Firmware Manual Firmware Version V2.0 | Document Revision V1.0 2018-Nov-07
68 / 86
Object Description
Index Name Object Type Data Type
606C
h
Velocity Actual Value Variable SIGNED32
Table 189: Object Description (606C
h
)
Entry Description
Sub- PDO
index Name Mapping Min Max Default Unit Access
0 Velocity Actual Value no -2147483648 2147483647 0 [rpm] R
Table 190: Entry Description (606C
h
)
8.2.4 Object 607C
h
: Home Oset
This object indicates the congured dierence between the zero position for the application and the
machine home position/home switch (found during homing). While homing, the machine home position is
found and once the homing is completed, the zero position is oset from the home position by adding the
home oset to the home position. The eect of setting the home position to a non-zero value depends on
the selected homing method. Negative values indicate the opposite direction.
Object Description
Index Name Object Type Data Type
607C
h
Home Oset Variable SIGNED32
Table 191: Object Description (607C
h
)
Entry Description
Sub- PDO
index Name Mapping Min Max Default Unit Access
0 Home Oset no -2147483648 2147483647 0 RW
Table 192: Entry Description (607C
h
)
8.2.5 Object 6098
h
: Homing Method
The actual homing method.
Object Description
Index Name Object Type Data Type
6098
h
Homing Method Variable SIGNED8
Table 193: Object Description (6098
h
)
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com