User Manual

Table Of Contents
PD42-x-1670 CANopen Firmware Manual Firmware Version V2.0 | Document Revision V1.0 2018-Nov-07
67 / 86
Operation Mode specic Bits in hm Mode
Bit Name Denition
10 Target reached
Set when the zero position has been found or homing has
been stopped by setting controlword bit 4 to zero.
12 Home attained Set when zero position has been found.
13 Homing error Not supported.
Table 185: Operation Mode specic Bits in hm Mode
State Coding
Status word FSA state
xxxx xxxx x0xx 0000
h
Not ready to switch on
xxxx xxxx x1xx 0000
h
Switch on disabled
xxxx xxxx x01x 0001
h
Ready to switch on
xxxx xxxx x01x 0011
h
Switched on
xxxx xxxx x01x 0111
h
Operation enabled
xxxx xxxx x00x 0111
h
Quick stop active
xxxx xxxx x0xx 1111
h
Fault reaction active
xxxx xxxx x0xx 1000
h
Fault
Table 186: State Coding
Object Description
Index Name Object Type Data Type
6041
h
Controlword Variable UNSIGNED16
Table 187: Object Description (6041
h
in hm Mode)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw see CiA402-3 See state coding above.
Table 188: Entry Description (6041
h
in hm Mode)
8.2.3 Object 606C
h
: Velocity Actual Value
This object shows the actual velocity value derived from the velocity sensor.
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.