Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 ro no UNSIGNED8 0
Table 8: Entry Description (1001
h
)
Error Register Bits
Bit Denition
0 Generic error
1 Current
2 Voltage
3 Temperature
4 Communication error
5 Device prole specic
6 Reserved (always 0)
7 Manufacturer specic
Table 9: Error Register Bits
3.1.3 Object 1005
h
: COB-ID SYNC Message
This object denes the COB-ID of the synchronization object (SYNC). Further, it denes whether the module
generates the SYNC.
Value Denition
Bit Name Denition
30 Generate 0: Device does not generate SYNC message
1: Device generates SYNC message
29 Frame Not supported, always set to 0.
28. . . 11 29 bit ID Not supported, always set to 0.
10. . . 0 11 bit ID 11 bit COB-ID.
Table 10: Value Denition (1005
h
)
Object Description
Index Name Object Type Data Type
1005
h
COB-ID SYNC message Variable UNSIGNED32
Table 11: Object Description (1005
h
)
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany