User Manual

PD42-1140 CANopen® Firmware Manual Firmware Version V3.20 | Document Revision V2.10 2018-DEC-01
41 / 109
4.2.19 Object 2094
h
: Chopper Hysteresis Decrement
This object serves for the hysteresis decrement setting. This setting determines the slope of the hysteresis
during on time and during fast decay time.
0 fast decrement
3 very slow decrement
Object Description
Index Name Object Type Data Type
2094
h
Chopper Hysteresis Decrement Variable UNSIGNED8
Table 90: Object Description (2094
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 3 0
Table 91: Entry Description (2094
h
)
4.2.20 Object 2095
h
: Chopper Hysteresis End
This object provides the setting of the hysteresis end value after a number of decrements. The decrement
interval time is controlled by object 2094
h
(section 4.2.19).
Possible values are:
-3. . . -1 negative hysteresis end setting
0 zero hysteresis end setting
1. . . 12 positive hysteresis end setting
Object Description
Index Name Object Type Data Type
2095
h
Chopper Hysteresis End Variable SIGNED8
Table 92: Object Description (2095
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no -3. . . 12 0
Table 93: Entry Description (2095
h
)
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com