All Global Parameters of the PD42-1141 Module in Bank 0
Number Global Parameter Description Range [Units] Access
65 RS485 baud rate
0 9600 Default
1 14400
2 19200
3 28800
4 38400
5 57600
6 76800
7 115200
8 230400
0. . . 8 RWA
66 Serial address Module (target) address for RS485. 1. . . 255 RWA
67 ASCII Mode Congure the TMCL ASCII interface:
Bit 0 0 - start up in binary (normal) mode
1 - start up in ASCII mode
Bits 4 & 5 00 - Echo back each character
01 - Echo back complete command
10 - Do not send echo, only send com-
mand reply
0. . . 63 RWA
68 Serial heartbeat
Serial heartbeat for RS485 interface and
USB interface. If this time limit is up and no
further command is received by the mod-
ule the motor will be stopped. Setting this
parameter to 0 (default) turns o the serial
heartbeat function.
0. . . 65535 RWA
75 Telegram pause
time
Pause time before the reply via RS485 is
sent. For use with older RS485 interfaces it
is often necessary to set this parameter to
15 or more (e.g. RS485 adapters controlled
by the RTS pin). For CAN interface this pa-
rameter has no eect!
0. . . 255 RWA
76 Serial host
address
Host address used in the reply telegrams
sent back via RS485.
0. . . 255 RWA
77 Auto start mode
0 - Do not start TMCL application after
power up (default).
1 - Start TMCL application automatically af-
ter power up.
0/1 RWA
79 End switch
polarity
0 - normal polarity
1 - reverse polarity
0/1 RWA