5 Functional Description
5.1 Typical Application Wiring
The PD42-1270 driver/controller’s wiring is straightforward as shown in the following figure.
• Power supply must be connected to V+ and GND.
• CAN - use appropriate CAN interface adapter
• ENN - connect ENN signal to GND in order to enable driver stage
Power supply
USB-CAN
c:>
Host
Figure 14: Typical application scenario for remote control of PD42-1270
5.2 Inputs
The four inputs of the PD42-1270 are +5V TTL compatible with internal pull-ups (10k) to +5V and
not
optically isolated.