8.2.5 Object 6098
h
: Homing Method
The homing method to be used can be selected by writing to this object. Please see table 282 for a list of
homing methods supported by the current version of the PD42-1270 CANopen firmware.
Object Description
Index Name Object Type Data Type
6098
h
Homing method Variable SIGNED8
Table 299: Object Description (6098
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no SIGNED8 0
Table 300: Entry Description (6098
h
)
8.2.6 Object 6099
h
: Homing Speeds
This object indicates the configured speeds used during homing procedure. The values are given in pps
units or inernal units selectable with object 208C
h
(section 4.2.16). Using object 6099
h
a fast and a slow
homing speed can be set. In most homing modes, the home switch is searched with the fast speed first.
When the home switch has been found, the motor will be decelerated to the slow speed (using the homing
acceleration, object 609A
h
) to search for the exact switch point. When the switch point has been found the
motor will be stopped at that point.
Object Description
Index Name Object Type Data Type
6099
h
Homing speeds Array UNSIGNED32
Table 301: Object Description (6099
h
)
Entry Description
Sub-index Description Access PDO Mapping Value Range Default Value
1 Fast homing speed rw no UNSIGNED32 0
2 Slow homing speed rw no UNSIGNED32 0
Table 302: Entry Description (6099
h
)
8.2.7 Object 609A
h
: Homing Acceleration
This object indicates the configured acceleration and deceleration to be used during homing operation.
The value is given in units selected by object 208E
h
(section 4.2.17).
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com