User Manual

PD42-1270 CANopen
®
Firmware Manual Firmware Version V3.19 | Document Revision V1.0 2017-Mar-02
96 / 106
Object Description
Index Name Object Type Data Type
6040
h
Controlword Variable UNSIGNED16
Table 287: Object Description (6040
h
in hm Mode)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw see CiA402-3 See command coding above.
Table 288: Entry Description (6040
h
in hm Mode)
8.2.2 Object 6041
h
: Status Word
This object provides the status of the PDS FSA. It reects the status of the CiA-402 state machine. Please
refer to gure 8 for detailed information. The object is structured as dened below.
For more information about the coding please refer to the CANopen Drives and motion control device
prole, part 2.
Structure of the Status Word
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
dir mot oms ila tr rm ms w sod qs ve f oe so rtso
MSB LSB
Legend: nu=not used; r=reserved; oms=operation mode specic; h=halt; fr=fault reset; eo=enable opera-
tion; qs=quick stop; ev=enable voltage; so=switch on.
Table 289: Structure of the Status Word in hm Mode
Trinamic Specic Bits
Bit Name Denition
14 Motor activity 0: Motor stands still.
1: Motor rotates.
15 Direction of rotation This bit shows the direction of rotation.
Table 290: Trinamic Specic Bits
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com
Read entire documentation.