User Manual

PD42-1270 CANopen
®
Firmware Manual Firmware Version V3.19 | Document Revision V1.0 2017-Mar-02
76 / 106
Object Description
Index Name Object Type Data Type
6067
h
Position Window Variable UNSIGNED32
Table 231: Object Description (6067
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no UNSIGNED32 FFFFFFFF
h
Table 232: Entry Description (6067
h
)
6.1.8 Object 6068
h
: Position Window Time
This object indicates the congured time, during which the actual position within the position window is
measured. The value is given in ms. If this object is set to a value greater than zero and also the position
window (6067
h
) is set to a value greater than zero the target reached event will not be signaled until the
actual position (6064
h
) is at least as many milliseconds within the position window as dened by this
object.
Object Description
Index Name Object Type Data Type
6068
h
Position Window Time Variable UNSIGNED16
Table 233: Object Description (6068
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no UNSIGNED16 0
Table 234: Entry Description (6068
h
)
6.1.9 Object 606C
h
: Velocity Actual Value
This object shows the actual velocity value of the motor. The value is given in internal or user-dened
velocity units (depending on object 208C
h
, described in section 4.2.16).
Object Description
Index Name Object Type Data Type
606C
h
Velocity Actual Value Variable SIGNED32
Table 235: Object Description (606C
h
)
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com
Read entire documentation.