Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 16777215 0
Table 133: Entry Description (20B6
h
)
4.2.42 Object 20B7
h
: High Speed Chopper Mode
The motor driver will switch to a different chopper mode when this object is set to 1 and the measured
speed is greater than the threshold speed set by object 20B6
h
(see section 4.2.41).
Object Description
Index Name Object Type Data Type
20B7
h
High Speed Chopper Mode Variable UNSIGNED8
Table 134: Object Description (20B7
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0/1 0
Table 135: Entry Description (20B7
h
)
4.2.43 Object 20B8
h
: High Speed Fullstep Mode
The motor driver will switch to fullstep mode when this object is set to 1 and the measured speed is greater
than the threshold speed set by object 20B6
h
(see section 4.2.41).
Object Description
Index Name Object Type Data Type
20B8
h
High Speed Chopper Mode Variable UNSIGNED8
Table 136: Object Description (20B8
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0/1 0
Table 137: Entry Description (20B8
h
)
4.2.44 Object 20B9
h
: Power Down Ramp
The value set by this object controls the number of clock cycles for motor power down after a motion as