4.2.20 Object 2094
h
: Chopper Hysteresis Decrement
This object serves for the hysteresis decrement setting. This setting determines the slope of the hysteresis
during on time and during fast decay time.
• 0 – fast decrement
• 3 – very slow decrement
Object Description
Index Name Object Type Data Type
2094
h
Chopper Hysteresis Decrement Variable UNSIGNED8
Table 90: Object Description (2094
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 3 0
Table 91: Entry Description (2094
h
)
4.2.21 Object 2095
h
: Chopper Hysteresis End
This object provides the setting of the hysteresis end value after a number of decrements. The decrement
interval time is controlled by object 2094
h
(section 4.2.20).
Possible values are:
• -3. . . -1 – negative hysteresis end setting
• 0 – zero hysteresis end setting
• 1. . . 12 – positive hysteresis end setting
Object Description
Index Name Object Type Data Type
2095
h
Chopper Hysteresis End Variable SIGNED8
Table 92: Object Description (2095
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no -3. . . 12 0
Table 93: Entry Description (2095
h
)
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com
Read entire documentation.