3.1.14 Object 1017
h
: Producer Heartbeat Time
The producer heartbeat time denes the cycle time of the heartbeat. The producer heartbeat time is 0 if it
is not used. The time has to be a multiple of 1ms.
Object Description
Index Name Object Type Data Type
1017
h
Producer heartbeat time Variable UNSIGNED16
Table 36: Object Description (1017
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no UNSIGNED16 0
Table 37: Entry Description (1017
h
)
3.1.15 Object 1018
h
: Identity Object
The object 1018
h
contains general information about the device:
The vendor ID (sub-index 01
h
) contains a unique value allocated to each manufacturer. The vendor
ID of Trinamic is 286
h
.
The manufacturer specic product code (sub-index 2
h
) identies a specic device version.
The manufacturer specic revision number (sub-index 3
h
) consists of a major revision number and a
minor revision number.
Object Description
Index Name Object Type Data Type
1018
h
Identity object Record Identity
Table 38: Object Description (1018
h
)
Entry Description
Sub-index Description Access PDO Mapping Value Range Default Value
00
h
Number of entries ro no 0. . . 3 3
01
h
Vendor ID ro no UNSIGNED32 0286
h
02
h
Product code ro no UNSIGNED32 1270
03
h
Revision number ro no UNSIGNED32 e.g. 20003
h
for version 2.3
Table 39: Entry Description (1018
h
)
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany