User Manual

PD42-1270 CANopen
®
Firmware Manual Firmware Version V3.19 | Document Revision V1.0 2017-Mar-02
22 / 106
On read access, each sub-index provides information if it is possible to restore the parameter group. It
reads 1 if yes and 0 if no.
After the default values have been restored they will become active after the next rest or power cycle of
the PD42-1270.
Object Description
Index Name Object Type Data Type
1011
h
Restore parameters Array UNSIGNED32
Table 27: Object Description (1011
h
)
Entry Description
Sub-index Description Access PDO Mapping Value Range Default Value
01h Restore all parameters rw no UNSIGNED32
02h Restore communication parameters rw no UNSIGNED32
03h Restore device prole parameters rw no UNSIGNED32
04h Restore motor axis 0 parameters rw no UNSIGNED32
Table 28: Entry Description (1011
h
)
3.1.11 Object 1014
h
: COB-ID Emergency Object
This object denes the COB-ID of the emergency object (EMCY).
Object Description
Index Name Object Type Data Type
1014
h
COB-ID emergency object Variable UNSIGNED32
Table 29: Object Description (1014
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no UNSIGNED32 80
h
+ Node ID
Table 30: Entry Description (1014
h
)
3.1.12 Object 1015
h
: Inhibit Time EMCY
The inhibit time for the EMCY message can be adjusted via this entry. The time has to be a multiple of
100µs.