User Manual

PD42-1240 TMCL
Firmware Manual Firmware Version V1.45 | Document Revision V1.02 2018-DEC-03
74 / 132
Binary Form of CALCXV SUB, 27
Field Value
Target address 01
h
Instruction number 2A
h
Type 01
h
Motor/Bank 1B
h
Value (Byte 3) 00
h
Value (Byte 2) 00
h
Value (Byte 1) 00
h
Value (Byte 0) 00
h
Checksum 47
h
Reply (Status=no error, value=0:
Field Value
Host address 02
h
Target address 01
h
Status 64
h
Instruction 2A
h
Value (Byte 3) 00
h
Value (Byte 2) 00
h
Value (Byte 1) 00
h
Value (Byte 0) 00
h
Checksum 91
h
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com