User Manual
PD42-1240 TMCL
™
Firmware Manual • Firmware Version V1.45 | Document Revision V1.02 • 2018-DEC-03
17 / 132
Command Number Parameter Description
AIV 57 Accumulator to indexed variable
Table 5: Overview of all TMCL Commands
3.5 TMCL Commands by Subject
3.5.1 Motion Commands
These commands control the motion of the motor. They are the most important commands and can be
used in direct mode or in standalone mode.
Motion Commands
Mnemonic Command number Meaning
ROL 2 Rotate left
ROR 1 Rotate right
MVP 4 Move to position
MST 3 Motor stop
SCO 30 Store coordinate
CCO 32 Capture coordinate
GCO 31 Get coordinate
Table 6: Motion Commands
3.5.2 Parameter Commands
These commands are used to set, read and store axis parameters or global parameters. Axis parameters
can be set independently for each axis, whereas global parameters control the behavior of the module
itself. These commands can also be used in direct mode and in standalone mode.
Parameter Commands
Mnemonic Command number Meaning
SAP 5 Set axis parameter
GAP 6 Get axis parameter
SGP 9 Set global parameter
GGP 10 Get global parameter
STGP 11 Store global parameter
RSGP 12 Restore global parameter
Table 7: Parameter Commands
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com