Datasheet
PD20-1-1210 Hardware Manual • Hardware Version V1.10 | Document Revision V1.20 • 2019-APR-03
10 / 24
5 On-Board LED
The board offers one LED in order to indicate board status. The function of this LED dependends on the
firmware version. With standard TMCL firmware the green LED should be flashing slowly during operation.
When there is no valid firmware programmed into the board or during firmware update the green LED will
be permanently switched on. During reset to factory default values the green LED will be flashing fast.
GREEN LED
Figure 3: PD20-1-1210 LED
6 Reset to Factory Defaults
It is possible to reset all settings in firmware for the PD20-1-1210 to factory defaults without establishing
a working communication connection. This might be helpful in case communication parameters of the
preferred interface have been set to unknown values or got lost.
For this procedure two pads on the bottom side of the module (electronics) have to be shorted (electrically
connected with each other) during power-on.
Please perform the following steps:
1. Switch power supply OFF (and disconnect USB cable if applicable)
2. Short CLK and DIO pads of programming pads on bottom of pcb (see figure 4)
3. Switch power supply ON again (or connect USB again if applicable)
4. Wait until the on-board red and green LEDs start flashing fast (this might take a while)
5. Switch power supply OFF again (and disconnect USB cable if applicable)
6. Remove short between pads
7.
After switching power supply ON again (and / or connecting USB cable) all permanent settings have
been restored to factroy defaults
Figure 4: Reset to factory default settings
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com