User manual
IDX Manual (V1.16 / December 3
rd
, 2008) 13
Copyright © 2005-2008, TRINAMIC Motion Control GmbH & Co. KG
0
2
4
6
8
10
12
14
0,3 0,8 1,3 1,8 2,3 2,8 3,3 3,8 4,3 4,8
ICOIL /A
L /mH
75 V 48 V 24 V
Figure 5.1: Maximum voltage regarding motor current and inductivity
Any combination of motor coil current and inductivity which is above the curve for
maximum supply voltage (V
S
) is possible to drive the motor in this mode.
0
0,5
1
1,5
2
2,5
1 1,5 2 2,5 3 3,5 4 4,5 5
ICOIL /A
L /mH
Check your motor data sheet, please.
If in doubt, please start with a lower supply voltage and check motor heating when raising the
voltage.