3.6.7  STAP (store axis parameter) 
An axis parameter previously set with a Set Axis Parameter command (SAP) will be stored permanent. Most 
parameters are automatically restored after power up (refer to axis parameter list in chapter 4). 
For a  table with parameters and values which can be used together with this command please refer to 
chapter 4. 
Internal function: An axis parameter value stored in SRAM will be transferred to EEPROM and loaded from 
EEPORM after next power up. 
Related commands: SAP, RSAP, GAP, AAP 
Mnemonic: STAP <parameter number>, 0 
Binary representation: 
INSTRUCTION NO. 
TYPE 
MOT/BANK 
VALUE 
7 
<parameter number> 
0*
1
(don't care)*
2
 *
1
motor number is always O as only one motor is involved 
 *
2
the value operand of this function has no effect. Instead, the currently used value (e.g. selected by SAP) is saved. 
Reply in direct mode: 
STATUS 
VALUE 
100 – OK 
(don't care) 
Parameter ranges: 
Parameter number 
Motor number 
Value 
s. chapter 4 
0 
s. chapter 4 
Example: 
Store the maximum speed of motor  
Mnemonic: STAP 4, 0 
Binary: 
Byte Index 
0 
1 
2 
3 
4 
5 
6 
7 
Function 
Target- 
address 
Instruction 
Number 
Type 
Motor/ 
Bank 
Operand 
Byte3 
Operand 
Byte2 
Operand 
Byte1 
Operand 
Byte0 
Value (hex) 
$01 
$07 
$04 
$00 
$00 
$00 
$00 
$00 
Note:  
The  STAP command will not have any  effect  when  the  configuration  EEPROM  is  locked  (refer to 5.1).  In 
direct mode, the error code 5 (configuration EEPROM locked, see also section 3.2.1) will be returned in this 
case. 