User manual
PD-1141 TMCL Firmware V1.19 Manual (Rev. 1.01 / 2012-JUL-27)  26 
www.trinamic.com   
Example: 
Move motor from current position 1000 steps backward (move relative –1000) 
Mnemonic: MVP REL, 0, -1000 
Binary: 
Byte Index 
0 
1 
2 
3 
4 
5 
6 
7 
Function 
Target- 
address 
Instructio
n 
Number 
Type 
Motor/ 
Bank 
Operand 
Byte3 
Operand 
Byte2 
Operand 
Byte1 
Operand 
Byte0 
Value (hex) 
$01 
$04 
$01 
$00 
$ff 
$ff 
$fc 
$18 
Example: 
Move motor to previously stored coordinate #8 
Mnemonic: MVP COORD, 0, 8 
Binary: 
Byte Index 
0 
1 
2 
3 
4 
5 
6 
7 
Function 
Target- 
address 
Instruction 
Number 
Type 
Motor/ 
Bank 
Operand 
Byte3 
Operand 
Byte2 
Operand 
Byte1 
Operand 
Byte0 
Value (hex) 
$01 
$04 
$02 
$00 
$00 
$00 
$00 
$08 
When moving to a coordinate, the coordinate has to be set properly in advance with the help of the 
SCO, CCO or ACO command. 