6.7.30 CLE (clear error flags)
This command clears the internal error flags. It is intended for use in stand-alone mode only and must
not be used in direct mode.
The following error flags can be cleared by this command (determined by the <flag> parameter):
ALL: clear all error flags.
ETO: clear the timeout flag.
EAL: clear the external alarm flag
EDV: clear the deviation flag
EPO: clear the position error flag
Related commands: JC
Mnemonic: CLE <flags>
where <flags>=ALL|ETO|EDV|EPO
Binary representation:
INSTRUCTION NO.
TYPE
MOT/BANK
VALUE
36
0 (ALL) all flags
1 (ETO) timeout flag
2 (EAL) alarm flag
3 (EDV) deviation flag
4 (EPO) position flag
5 (ESD) shutdown flag
(don't care)
(don't care)
Example:
Reset the timeout flag
Mnemonic: CLE ETO
Binary:
Byte Index
0
1
2
3
4
5
6
7
8
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Checksum
Value (hex)
$01
$24
$01
$00
$00
$00
$00
$00
$26