User manual
TMCM-6110 TMCL Firmware V1.19 Manual (Rev. 1.03 / 2012-JUL-31) 34
www.trinamic.com
5.6.12 RSGP (restore global parameter)
With this command the contents of a TMCL user variable can be restored from the EEPROM. For all
configuration-related axis parameters, non-volatile memory locations are provided. By default, most
parameters are automatically restored after power up. A single parameter that has been changed before
can be reset by this instruction.
Internal function: The specified parameter is copied from the configuration EEPROM memory to its RAM
location.
Relate commands: SGP, STGP, GGP, and AGP
Mnemonic: RSGP <parameter number>, <bank number>
Binary representation:
INSTRUCTION NO.
TYPE
MOT/BANK
VALUE
12
<parameter number>
<bank number>
don’t care
Reply structure in direct mode:
STATUS
VALUE
100 – OK
don’t care
For a table with parameters and bank numbers which can be used together with this command please
refer to chapter 7.
Example:
Restore the user variable #42
Mnemonic: RSGP 42, 2
Binary:
Byte Index
0
1
2
3
4
5
6
7
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Value (hex)
$01
$0c
$2a
$02
$00
$00
$00
$00