User manual
TMCM-1161 TMCL Firmware V1.19 Manual (Rev. 1.04 / 2012-NOV-19)  21 
www.trinamic.com   
3.5.2  ROL (rotate left) 
With  this  command  the  motor  will  be  instructed  to  rotate  with  a  specified  velocity  (opposite  direction 
compared to ROR, decreasing the position counter). 
Internal function: First, velocity mode is selected. Then, the velocity value is transferred to axis parameter 
#0 (target velocity).  
The module is based on  the  TMC429 stepper motor controller and  the  TMC262 power driver.  This  makes 
possible choosing a velocity between 0 and 2047.  
Related commands: ROR, MST, SAP, GAP 
Mnemonic: ROL 0, <velocity> 
Binary representation: 
INSTRUCTION NO. 
TYPE 
MOT/BANK 
VALUE 
2 
(don't care) 
0* 
<velocity> 
0… 2047 
*motor number is always O as only one motor is involved 
Reply in direct mode: 
STATUS 
VALUE 
100 – OK 
(don't care) 
Example: 
Rotate left, velocity = 1200 
Mnemonic: ROL 0, 1200 
Binary: 
Byte Index 
0 
1 
2 
3 
4 
5 
6 
7 
Function 
Target- 
address 
Instruction 
Number 
Type 
Motor/ 
Bank 
Operand 
Byte3 
Operand 
Byte2 
Operand 
Byte1 
Operand 
Byte0 
Value (hex) 
$01 
$02 
$00 
$00 
$00 
$00 
$04 
$b0 