Trina Allmax M Plus Solar Module Installation Manual (IEC-UL)
Table Of Contents
Date: April, 2016 DOC: PS-M-0434 A Page - 5 - of 15
the module is mounted with hardware that has been tested and evaluated with the module under this standard or by a
field Inspection certifying that the installed module complies with the requirements of UL1703.
3. UNPACKING AND STORAGE
• At time of receipt, verify that the product delivered is in fact the product ordered. The product name, subname, and
serial number of each laminate are clearly marked on the outside of each packing box.
• Leave the product in its original packing box until you are ready to install.
• Store packing boxes in a clean, dry area with relative humidity below 85% and ambient temperatures between -20°C
and 50°C.
• Do NOT stack more than the maximum amount of allowable pallets on top of each other.
• At the installation site, take care to keep modules and particular their electrical contacts clean and dry before
installation. If connector cables are left in damp conditions then the contacts may corrode. Any module with
corroded contacts should not be used.
• If pallets are stored temporarily outside then place a protective covering over the pallet to protect it from direct
weathering and do not stack more than 1 pallet high.
• Two people are required to unpack the modules from the packing box, when handling modules always use both
hands.
• Protect the module edges for temporary storage outside the pallet.
• Do NOT use a knife to cut the zip-ties, but use wire cutting pliers.
• Do NOT place modules directly on top of each other.
3.1 PRODUCT IDENTIFICATION
Each individual module has a unique serial number laminated behind the glass and another permanently attached to
the back-sheet of the module on the product sticker. Note all serial numbers in an installation for your future
records.
4. ENVIRONMENTAL CONSIDERATIONS
4.1 CLIMATE CONDITIONS
Trina Solar Crystalline series modules may be installed in the following conditions for more than 25 years. In
addition to the required IEC certification, Trina Solar products have also been tested to verify resistance to
ammonia fumes that may be present around barns sheltering cattle, as well as suitability for installation in humid
(coastal) areas and areas of high sand storms.
Environment
• Ambient temperature: -40°C to 50°C
• Operating temperature: -40°C to +85°C
• Storage temperature: -20°C to +50°C
• Humidity: < 85RH%
• Mechanical Load Pressure*:5400Pa (550 Kg/m²) Max from the front side (snow) & 2400Pa (wind) from the rear
(Except Installation Method C: Mounting with
Single-axis Tracking System - 2400Pa (snow) & 2400Pa (wind)