Trina Allmax M Plus Solar Module Installation Manual (IEC-UL)

Date: April, 2016 DOC: PS-M-0434 A Page - 15 - of 15
In the event that a module is damaged (broken glass or scratch on back sheet) and needs to be replaced then
Observe the safety precautions listed earlier in the manual
Wear cut resistant gloves and other personal protective equipment required for the particular installation.
Isolate the impacted array string to prevent current flow before attempting to remove the module.
Disconnect the connectors of the affected module using the related disconnect tool provided by suppliers.
Replace the damaged module with a new module of the same type.
Check the open circuit voltage of the array string and verify that this is within 10V of the other strings to be
connected in parallel.
Turn the isolator back on.
Troubleshooting:
If your installation does not work properly, please inform your installer immediately.
Reporting Technical Issues or Claims:
Contact your installer
Contact Trina Solar after sales service team at http://customerservice.trinasolar.com
Submit the Customer Feedback form at: http://www.trinasolar.com/ and one of our technical service
representatives will contact you within 5 business days. A username and password is required to send feedback
from the customer service link
For module specifications or datasheets, please download from: http://www.trinasolar.com/
9. WARNING
WARNING: For any electrical maintenance, the PV system must first be shut down. Improper maintenance can
cause lethal electric shock and/or burns.