Installation Manual
Table Of Contents
- 1. DISCLAIMER OF LIABILITY .............................................................................................................. - 3 -
 - 5.1 CLIMATE CONDITIONS
 - 5.2 SITE SELECTION
 - 6.1 MOUNTING METHODS
 - B. Mounting with Clamps
 - C. Mounting with Single-axis Tracking System
 - 6.2 GROUNDING
 - 6.3 MODULE WIRING
 - 7.1 FUSING
 - 7.2 INVERTER SELETION AND COMPATIBILITY
 
Date: 2018.7.16 
Doc No: PS-M-0434 
Ver. D 
Page - 11 - of 17 
Clamping system 
Attachment to the long frame 
This is Only for TSM-DC03A.08(II) 
This is Only for TSM-PC05B 
Clamping system 
Attachment to the short 
frame 
Other mounting configurations can be used. However, failure to comply with the above recommendations will 
result in a lowering of the load handling (snow/wind load) capabilities below the product specification 
5400/2400Pa (IEC), 30 lbs.ft
2 
(UL1703) and product failure as a result of an overload situation will not be covered 
by the Trina Solar warranty. 
C. Mounting with Single-axis Tracking System 
•  This installation is only for 72 cells polycrystalline modules. 
•  It is a Single-axis Tracking System, the module is fixed on the axis by bolting long frame. 
•  The frame of each module has 4-φ7*10mm(0.28*0.39in) mounting holes with specific location shown 
in Figure 3. 
•  Secure the module in each fixing location with an M6 bolt, two flat washers, a spring washer and nut 
as shown in Figure 3. 
•  If a different bolt similar to M6 is used, they need to be tightened to a torque of 16N.m.(140lbf.in). 
•  All parts in contact with the frame should use flat stainless steel washers of minimum 1.5mm thickness 
with an outer diameter of 16-20mm (0.63-0.79in.). 
•  The bolt should be made of stainless steel or the other anti-corrosion material. 
•  Mechanical Load Pressure under this method: 30 lbs.ft
2 
(snow) max from the front side & 30 lbs.ft
2
(wind) max from the rear according to UL1703. 