User's Manual
TrimTrac ProE Locator Technical Manual v2.0e 58
Figure 9. Control Module with Stand-by Battery Leads Connected
OPTIONAL INPUTS AND ALERTS:
1. Refer to the Vehicle Adapter and Control Module wiring diagrams
provided in the Technical Manual, in Figure 36 or Figure 37 on pages
213 and 214, respectively.
2. Mount the monitored input switches or devices in the desired
locations. It is best to install resistors with the values specified on the
wiring diagram at the monitored switch or device (instead of at the
TrimTrac ProE). In so doing, maximum tampering protection is
afforded.
3. Install a 100K-Ohm End-of-Line resistor as shown in the wiring
diagram, if Medium Priority Alerts are to be used.
OPTIONAL OUTPUTS (Control Module Only):
1. Refer to the Control Module wiring diagram provided in the Technical
Manual, in Figure 37 on page 214.
2. The ORANGE (Output 1) and BLUE (Output 2) wires can be
connected directly to loads of less than 500 mA @ 12 VDC. ,
respectively. Larger loads should be controlled via an automotive
grade relay.
FINAL ASSEMBLY AND INSTALLATION:
1. Configure and provision the TrimTrac ProE as described in “TrimTrac
ProE Configuration” beginning on page 109. Generally, the device