User's Manual
TrimTrac ProE Locator Technical Manual v2.0e 173
RESP_EXT2_APP_CONFIG
This is the response message to the SET_EXT2_APP_CONFIG (page 152) and
QUERY_CONFIG (page 161)message containing the Extended 2 Application
Parameter values.
>RTKABBBBCDDDDDEEEEEFGHIJJJKKKLMNNNOQQQUVVVVVVXXXXXXXX
XXXXXXXXXXXXXXX;ID=YYYYYYYY;*ZZ<
A
TrimTrac ProE Configuration Set: āZā = Extended 2
Application Parameters
BBBB
Motion Counter Threshold: Counter (1-2000). Default 10
C
Scheduled Hours Mode: 0=Disabled; 1=Enabled. Default 0
DDDDD
Scheduled Hours Daily Start Time, T27: In Seconds (0 ā
86399) after 12:00AM UTC.. Default 0
EEEEE
Scheduled Hours Work Day Length, T28: In Seconds (0 ā
86400). Default 43200
F
Scheduled Hours First Weekly Work Day: 0=Sunday;
1=Monday; 2=Tuesday; 3=Wednesday; 4=Thursday; 5=Friday;
6=Saturday (All relative to UTC). Default1
G
Scheduled Hours Work Days per Week: 1= One Day; 2=Two
Days; 3=Three Days; 4=Four Days; 5=Five Days; 6=Six Days;
7=Seven Days. Default 5
H
Runtime Motion-based: 0=Disabled; 1=Enabled. Default 0.
I
Runtime LPA-based: 0=Disabled; 1=Enabled. Default 0
JJJ
Runtime Motion-based Countdown, T29: In Hours (0=No
Countdown, 1-990). Default 0
KKK
Runtime LPA-based Countdown, T30: In Hours (0=No
Countdown, 1-990). Default 0
L
Automatic Message Log Dump: 0=Disabled; 1=Enabled.
Default 0
M
GPS Fix Rate: 0=GPS operation during FIX State only; 1=1Hz
GPS operation except while stationary. Default 0
NNN
LPA Input Arming Delay, T31: In Seconds (0-990). Default 0
0
Geofence Type: 0=Boundary Crossing; 1=Inclusive;
2=Exclusive
QQQ
Speed Enforcement: 0=No Enforcement; 1-990 = Limit in
MPH. Default 0.
U
Speeding Report Mode: 0=Report All Violations; 1=Report
Initial Violations Only. Default 0.
VVVVV
Speeding Countdown Timer: In Seconds (0-99990). Default 0.
XXXXXX
XXXXXX
XXXXXX
XXXXX
(23
chars)
Reserved. Must be 0.
YYYYYYYY
Unit ID. Always 8 alphanumeric characters, UPPER CASE ONLY