• Upon expiration of the IDLE Timeout, T1, the TriggerType is set
“0=IDLE Timeout, T1”, the TrimTrac 1.5 will transition to the
STATUS state (bypassing the FIX state).
•
If motion is detected while in the IDLE state, the TrimTrac 1.5 will
activate the Static Motion Filter Timeout, T7, and apply the Static
Motion Filter Counter, N3. (Rapid LED Blinking)
If there is sufficient continued motion, the TriggerType becomes set
“1=Motion Detected” and the unit will transition to the FIX State if the
Motion Report Flag is set “0=None” or to the STATUS state if the
Motion Report Flag is set “1=Report IDLE Motion”. If there is
insufficient motion to satisfy the Static Motion Filter Counter, N3,
while the Static Motion Filter Timeout, T7, is running, then the unit
will return to the IDLE state sleep mode and wait for a subsequent
TriggerType event to occur.
•
If an alert status is in some state other than “0=Normal” or “4=Monitor
Activated” or upon an initial Geofence violation, then the TriggerType
shall be set “2=Alert” and the device shall transition from the IDLE
State in accordance with its current configuration. See the section
below for more details on input alert processing.
• If the Anytime Polling is set to “2=Anytime OnDemand”, the unit
keeps the GSM modem operational and the device is ready to receive
messages from the sever at any time while the IDLE Timeout, T1, is
running (Continuous Rapid LED Blinking). Upon receipt of any data
messages, the TriggerType is set “3=Query” and the unit transitions
immediately to the QUERY state to process any such received
messages.
• If the Anytime Polling is set to “1=Duty-Cycled”, the TrimTrac 1.5
will power duty-cycle the GSM modem on and off during the IDLE
state. Each time the Polling Duty-Cycle Frequency, T19, timer
expires, the GSM modem will power up and the Polling Duty-Cycle
On-Time, T20, will start (Rapid LED Blinking). The GSM modem
hardware will remain on until the expiration of Polling Duty-Cycle
On-Time, T20, or a query message is received. Upon receipt of any
query messages, the TriggerType is set “3=Query” and the unit
transitions immediately to the QUERY state to process any such
received messages; else it goes back into IDLE sleep until the next
TriggerType event occurs or the next time the Polling Duty-Cycle
Frequency, T19, timer expires.
•
If the Scheduled Reporting Mode is set to either “1=Daily” or
“2=Weekly” the TriggerType will be set “4=Scheduled Report” upon
expiration of Scheduled Report Time, T18, timer regardless of the
Report Delay Flag setting.