User's Manual
DRAFT TrimTrac 1.5 Technical Manual v0.3ab 32
WARNING:
Before inserting a Vehicle Adapter or Control Module into a TrimTrac base
unit:
A) Connect the red (+) and black (-) wires to a 9-32 VDC power source and
install a 100k Ohm resistor across the yellow wires; OR
B) Set the TrimTrac MPA Mode to “1=Disabled”.
FAILURE TO DO EITHER OF THESE WILL CAUSE THE TRIMTRAC
1.5 TO IMMEDIATELY ACTIVATE A MEDIUM PRIORITY ALERT
AND BEGIN TRANSMITTING NOMINALLY EVERY 2-3 MINUTES
UNTIL AN ACKNOWLEDGEMENT IS RECEIVED.
Use the AT+CTKY command as shown below to disable all alerts.
Disable ALL MODULE alerts
See
Page
AT+CTKY= 97
Table 14, Disable Module Alert Configuration Settings