DRAFT TrimTrac 1.5 Technical Manual v0.3ab 165
Figure 9, Vehicle Adapter Module Alert Wiring Diagram
Notes:
High and Low Priority switches must be Normally Open; Medium Priority switch must be Normally Closed
HPA and MPA Switches can be either Momentary or Latching, LPA switch must latching-type
High, Low and Medium Switches are optional and can be used in any combination
Multiple switches can be used in parallel in each branch circuit; provided, however that branch resistance
values are maintained as shown.
End-of-Line Resistor is required unless MPA Mode is set “1=Disabled”
If Alert Switches are not used, then set HPA, MPA and LPA Modes all to “1=Disabled”
Set MPA Mode to “1=Disabled” if you do not want a MPA message if no external VDC is available.
All resistors (+/- 5%, .250 Watt min.) and switches provided by installer.
Opens, shorts and ground faults on main circuit and loss of external VDC handled as “Medium Priority Alerts”
New High and Low Priority alerts may not be recognized if a Medium Priority alert caused by an open, short or
ground fault is in already in effect.
TrimTrac Vehicle
Adapter Module
9-32 VDC
Positive (+)
Negative (-)
Re
d
Blac
Medium
Priority
Switch
(NC)
End-of-Line
Resistor
100k Ohm
Low
Priority
Switch
(NO)
LPA Resistor
37.4k Ohm
Yellow
High
Priority
Switch
(NO)
HPA Resistor
4.7k Ohm
Yellow