User's Manual

DRAFT TrimTrac 1.5 Technical Manual v0.3ab 157
Read-Only Parameters, Formats and Ranges
Parameter Value Messages
Protocol Sequence Number 16-bit Hex (0000-FFFF) incrementing by 1 for each logged report
TriggerType 0=IDLE Timeout
1=Motion Detected
2=Alert set “Activated” (Modules-Only)
3=Query
4=Scheduled Report
5=Runtime Meter Report
6=Stop Motion Report
Battery Level 0-100%
Battery Changed Flag T=True; F=False
GPS Week Number Always 4 Digits
GPS Seconds into Week Always 6 Digits
GPS Status Code 0=3D GPS Fix
1=2D GPS Fix
2=Fix Timeout, 0 SVs
3=Fix Timeout, 1 SV
4=Fix Timeout, 2 SVs
5=Fix Timeout, 3 SVs
6=GPS Error
7=No Fix attempted
Extended GPS Status code 0=Internal Antenna, Almanac Complete
1=External Antenna, Almanac Complete
2=Int. Antenna, Almanac Incomplete
3=Ext.Antenna, Almanac Incomplete
Note: Always 0 if GPS Status Code set to 7
>RTKP
>RTKS